Model Specification

Technical Parameters

Electrical Wiring

Size Structure

Installation Method

Model Number

Axis Distance

Number Of Light Beams

Protection Height mm (H)

Detection Distance

Output Method

Inquiry

Axis Distance
Number Of Light Beams
condition:
clear condition

KT10-174 1730NA

10mm

174

1730

0.3-3m (6m)

N/P

KT10-172 1710NA

10mm

172

1710

0.3-3m (6m)

N/P

KT10-170 1690NA

10mm

170

1690

0.3-3m (6m)

N/P

KT10-168 1670NA

10mm

168

1670

0.3-3m (6m)

N/P

KT10-166 1650NA

10mm

166

1650

0.3-3m (6m)

N/P

KT10-164 1630NA

10mm

164

1630

0.3-3m (6m)

N/P

KT10-162 1610NA

10mm

162

1610

0.3-3m (6m)

N/P

KT10-160 1590NA

10mm

160

1590

0.3-3m (6m)

N/P

KT10-158 1570NA

10mm

158

1570

0.3-3m (6m)

N/P

KT10-156 1550NA

10mm

156

1550

0.3-3m (6m)

N/P

KT10-154 1530NA

10mm

154

1530

0.3-3m (6m)

N/P

KT10-152 1510NA

10mm

152

1510

0.3-3m (6m)

N/P

KT10-150 1490NA

10mm

150

1490

0.3-3m (6m)

N/P

KT10-148 1470NA

10mm

148

1470

0.3-3m (6m)

N/P

KT10-146 1450NA

10mm

146

1450

0.3-3m (6m)

N/P

< 1...404142...46 > proceed page

 

performance
response time Typical values 50ms
Basic error 40mm
Statistical Error 30mm
Channel 64 (each channel contains 3 detection areas)
Detect output delay 0ms-500ms Can be set within the scope
Detect and maintain delay 0ms-500ms Can be set within the scope
Detecting object size and filtering angle 0.5°-5°Can be set within the scope
interface
configure port 1(Micro-UsB)
Switching input 6 (NPN)
Switching Output 4 (3 detection signals, 1 fault signal), single load capacity of 100mA
pilot lamp 4 (3 detection signal lights, 1 status light)
Electrical performance
working voltage DC18 -32V
Consumption current Typical value of 60mA (under no output load)
work environment
Object reflectivity 5%-1000%
work environment -25℃-50℃
Ambient Light Intensity less than 15000lx

 