Model Specification

Technical Parameters

Electrical Wiring

Size Structure

Installation Method

Model Number

Axis Distance

Number Of Light Beams

Protection Height mm (H)

Detection Distance

Output Method

Inquiry

Axis Distance
Number Of Light Beams
condition:
clear condition

KT14-188 2618NA

14mm

188

2618

0.3-3m (6m)

N/P

KT14-186 2590NA

14mm

186

2590

0.3-3m (6m)

N/P

KT14-184 2562NA

14mm

184

2562

0.3-3m (6m)

N/P

KT14-182 2534NA

14mm

182

2534

0.3-3m (6m)

N/P

KT14-180 2506NA

14mm

180

2506

0.3-3m (6m)

N/P

KT14-178 2478NA

14mm

178

2478

0.3-3m (6m)

N/P

KT14-176 2450NA

14mm

176

2450

0.3-3m (6m)

N/P

KT14-174 2422NA

14mm

174

2422

0.3-3m (6m)

N/P

KT14-172 2394NA

14mm

172

2394

0.3-3m (6m)

N/P

KT14-170 2366NA

14mm

170

2366

0.3-3m (6m)

N/P

KT14-168 2338NA

14mm

168

2338

0.3-3m (6m)

N/P

KT14-166 2310NA

14mm

166

2310

0.3-3m (6m)

N/P

KT14-164 2282NA

14mm

164

2282

0.3-3m (6m)

N/P

KT14-162 2254NA

14mm

162

2254

0.3-3m (6m)

N/P

KT14-160 2226NA

14mm

160

2226

0.3-3m (6m)

N/P

< 1...333435...46 > proceed page

 

performance
response time Typical values 50ms
Basic error 40mm
Statistical Error 30mm
Channel 64 (each channel contains 3 detection areas)
Detect output delay 0ms-500ms Can be set within the scope
Detect and maintain delay 0ms-500ms Can be set within the scope
Detecting object size and filtering angle 0.5°-5°Can be set within the scope
interface
configure port 1(Micro-UsB)
Switching input 6 (NPN)
Switching Output 4 (3 detection signals, 1 fault signal), single load capacity of 100mA
pilot lamp 4 (3 detection signal lights, 1 status light)
Electrical performance
working voltage DC18 -32V
Consumption current Typical value of 60mA (under no output load)
work environment
Object reflectivity 5%-1000%
work environment -25℃-50℃
Ambient Light Intensity less than 15000lx

 